Insulation Resistance
Test voltage | 250V/500V/1000V |
---|---|
Measuring ranges (Mid-scale value) |
100MΩ/200MΩ/400MΩ (1MΩ) (2MΩ) (4MΩ) |
Output voltage on open circuit | Rated test voltage+20%, -0% |
Nominal current | 1mA DC min. |
Output short circuit current | 1 – 2mA DC |
Accuracy | 0.1 – 10MΩ/0.2 – 20MΩ/0.4 – 40MΩ (Accuracy Guaranteed Ranges) ±5% of indicated value |
Continuity
Measuring ranges (Mid-scale value) |
3Ω/500Ω (1.5Ω) / (20Ω) |
---|---|
Output voltage on open circuit | 4.1V DC approx. |
Measuring current | 210mA DC min. |
Accuracy | ±1.5% of scale length |
AC Voltage
AC Voltage | 0 – 600V AC |
---|---|
Accuracy | ±5% of scale length |
General
Safety Standard | IEC 61010-1 CAT III 600V Pollution Degree 2 IEC 61010-2-031 IEC 61557-1/2/4 |
---|---|
IP Rating | IEC 60529-IP54 |
EMC Standard | IEC 61326-1 |
Power source | R6 (AA) (1.5V) × 6 |
Dimensions | 106(L) × 160(W) × 72(D)mm |
Weight | 560g approx. |
Included Accessories | 7122B (Test leads) Pouch for test leads 8923 (F500mA/600V fuse) × 2 R6 (AA) × 6 9121 (Shoulder Strap) Instruction Manual |